GSTDTAP  > 地球科学
Lose weight of fusion reactor component
admin
2020-06-29
发布年2020
语种英语
国家美国
领域地球科学 ; 气候变化
正文(英文)
IMAGE

IMAGE: (IMAGE 1) The superconducting coil consists of two pairs of helical coils and two sets of circular vertical magnetic field coils. In order to prevent the coil from moving or... view more 

Credit: National Institute for Fusion Science

The group of associate professor Hitoshi Tamura and others of the National Institute of Natural Sciences (NINS) National Institute for Fusion Science (NIFS) first applied topology optimization technique to the concept design of a helical fusion reactor which aims to demonstrate power generation. The group successfully achieved a weight reduction of about 2,000 tons of the support structure surrounding helically twisted coils while maintaining the strength of the structure.

A superconducting coil is essential to realize a magnetic fusion power reactor, in which plasma is required to be confined by a strong magnetic field. The superconducting coil is made of a superconducting conductor wound several hundred times and the coil generates a strong magnetic field by passing a large current flow of about 100 kiloamperes. An electromagnetic force is generated when a magnetic field acts on a coil in which an electric current flows. This electromagnetic force is so large that the superconducting coil itself cannot withstand this force. To prevent causing the coil to move or deform extremely, it is necessary to firmly surround the coil with a structure made of a strong material to support the coil. This structure is called a coil support structure (IMAGE 1).

So far, the weight of the coil support structure of the helical fusion reactor has been estimated to be 20 times heavier than that of the Large Helical Device (LHD) and 1.6 times that of the International Thermonuclear Experimental Reactor (ITER). In addition, since the superconducting coils are operated at cryogenic conditions (below minus 260 degrees Celsius), the heavy and solid coil support structure also needs to be cooled to the same temperature as the coils to maintain the coils in the superconducting state. Reducing an amount of materials is an extremely important issue from the viewpoints of cost and power consumption. It is strongly desired to reduce the total weight of the coil support structure as much as possible while maintaining the role of sustaining the coil. To solve this issue, the research group applied the "topology optimization method" to the design of the coil support structure. Topology optimization is an analytical method to reduce the volume of the structure by removing the part that does not affect the strength. It is equivalent to searching for the optimum shape from various combinations including the change of the topology. This method has the potential to create shapes that cannot be imagined based on conventional designs. Since it is extremely effective in reducing the weight and cost such as automobile parts, it has developed rapidly in recent years. However, there has been no example of application of the topology optimization to overall design of a component in the fusion reactor.

The research group applied the topology optimization method for the first time to the overall design of the structure in a huge and complicated fusion reactor to reduce its weight. The stress force acting in the structure determines the strength of the structure. If the stress is larger than the acceptable level of the component material, the structure will start breaking. Structural optimization should be done so that the stress does not exceed acceptable levels by reducing weight. The research group analyzed in detail what level of stress and deformation would act on the coil support structure due to the electromagnetic force acting on the coil. Then, topology optimization was applied to the model. In topology optimization, the model is divided into many small regions and the degree of influence on the overall strength when a certain region is removed is calculated. Finally, a set of regions that can be removed without any influence is determined. In this way, the optimum shape that does not affect the overall strength and has reduced weight was found. Consequently, the weight of the coil support structure was successfully reduced by about 25% from 7,800 tons.

In the future, it is expected that the fusion reactor design research using the topology optimization method will make further progress, and we will greatly approach the demonstration of the fusion reactor.

###

This research result was published as H. Tamura et al. "Topology optimization for superconducting magnet system in helical fusion reactor" in Journal of Physics: Conference Series 1559 in June 2020.

Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.

URL查看原文
来源平台EurekAlert
文献类型新闻
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/278272
专题地球科学
气候变化
推荐引用方式
GB/T 7714
admin. Lose weight of fusion reactor component. 2020.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[admin]的文章
百度学术
百度学术中相似的文章
[admin]的文章
必应学术
必应学术中相似的文章
[admin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。