GSTDTAP  > 气候变化
Patients' breathing test comes up short on accuracy, study finds
admin
2020-09-27
发布年2020
语种英语
国家美国
领域气候变化 ; 地球科学 ; 资源环境
正文(英文)

A routine test used to monitor patients' breathing may be unreliable and putting them at risk, a study suggests.

Incorrect results can mean clinical staff fail to spot how unwell a patient with respiratory problems is becoming, researchers say.

This widely used method, which counts breaths over a 30-second period, fails to take account of people's irregular breathing patterns, the team says.

The practice - key to assessing risk in many Covid-19 cases - could be improved by increasing the time of measurement to two minutes, the study concluded.

A team from the University of Edinburgh focused on what is referred to as the respiratory rate, which is the measurement of the number of breaths a person takes in one minute.

The rate is measured in all patients who arrive to hospital feeling unwell, as part of what is known as a warning score chart.

Most clinical staff believe that counting breaths taken over a 30-second period will give a reasonable measure of the respiratory rate, the researchers say.

As breathing is not always regular, however, there can be a variation in the respiratory rate when measuring it over a short time period.

The team analysed recordings of breathing in 25 hospital patients to determine how wide this variation can be. Each recording was made for between 30 minutes and an hour in patients with illnesses that included respiratory, cardiac, neurological and urinary conditions.

Researchers sampled the recordings at random, many times, in the same way the way clinical staff might measure the breathing rate.

It was found that there was a large variation in the respiration rate for each patient - more than half of the measurements differed by more than three breaths per minute.

This change may sound small but, in 40 per cent of cases, the incorrect rate would have meant the warning score chart was wrong.

The study is published in ERJ Open Research.

Dr Gordon Drummond, Honorary Clinical Senior Lecturer, from University of Edinburgh, said: "The lack of accuracy in measurement of respiration rate could have an impact on a patient's treatment. We think accuracy would be improved by increasing the time of measurement to two minutes and using specialist equipment to measure respiratory rate."

###

Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.

URL查看原文
来源平台EurekAlert
文献类型新闻
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/295936
专题气候变化
地球科学
资源环境科学
推荐引用方式
GB/T 7714
admin. Patients' breathing test comes up short on accuracy, study finds. 2020.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[admin]的文章
百度学术
百度学术中相似的文章
[admin]的文章
必应学术
必应学术中相似的文章
[admin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。